Skip to main content

Table 1 Amplification efficiency determined by various methods of real-time PCR data analysis. Arithmetical means ± SD and coefficients of variation (in parentheses) are shown.

From: Relative quantification of mRNA: comparison of methods currently used for real-time PCR data analysis

Gene/Method

Standard curve

DART-PCR

LinRegPCR

Liu&Saint-exp

IL-1β

0.998

1.033 ± 0.061 (5.95)

0.950 ± 0.074 (7.76)

0.974 ± 0.033 (3.42)

IL-6

0.900

0.912 ± 0.046 (5.05)

0.881 ± 0.075 (8.51)

0.870 ± 0.029 (3.35)

TNF-α

1.012

1.033 ± 0.024 (2.32)

0.974 ± 0.072 (7.45)

0.991 ± 0.032 (3.32)

GM-CSF

0.918

0.978 ± 0.044 (4.49)

0.932 ± 0.063 (6.75)

0.898 ± 0.013 (1.44)

ACTB

0.981

1.086 ± 0.046 (4.21)

0.999 ± 0.031 (3.10)

0.978 ± 0.044 (4.53)

SDHA

0.967

1.072 ± 0.052 (4.88)

0.980 ± 0.064 (6.55)

1.017 ± 0.044 (4.27)

HPRT

1.022

1.069 ± 0.064 (5.95)

0.978 ± 0.109 (11.1)

0.976 ± 0.048 (4.49)